About Us | Contact Us
  • +44 (0) 1403 799979
  • +1 703 433 9247

Error message

Warning: file_get_contents(http://ipinfo.io/3.144.249.63/country): failed to open stream: HTTP request failed! HTTP/1.0 429 Too Many Requests in include_once() (line 656 of /home/closuretesting/public_html/sites/default/settings.php).
helixa_slide1.jpg
Helixa
Precision measurement of caps and closures
helixa_slide2.jpg
Top-loading capability
Apply set loads during torque testing, particularly suitable for child-resistant closures
helixa_slide3.jpg
Interchangeable intelligent torque cells
Measure from a few mN.m up to 6 N.m

Measure closure torque to the highest accuracy down to very low values

The Helixa is designed for precision closure design applications, where torque forces may be very small and where accuracy is paramount. Interchangeable torque cells range from 0.1 N.m to 6 N.m capacity.

Precise user-adjustment of axial alignment ensures accuracy of measurement of very low closure torques

The drive spindle can be user-aligned for precise concentricity with the intelligent torque cell for optimum accuracy, and repeatability, adjustable to each fixture combination. Essential when testing at extremely low torque.

Apply axial loading to push down CRC push and turn capsLoad tray for applying a predefined axial load e.g. when push-off twist testing child-resistant closures.
Torque measurement and pass or fail criteria are clearly displayedCounterbalance capability for eliminating the weight of a grip being applied to a sample. Significant when testing precise torque at low forces.
Create test programs, perform calculations, and display closure torque measurement graphs
  •  Helixa-i is controlled by Mecmesin’s powerful Emperor™ software, with full sophisticated programming and results calculation, and user-profiled reporting and exporting facilities
  •  Helixa-xt is controlled by Emperor-xt, designed especially for intuitive touch-screen use requiring minimal training for repetitive use. It also has easy-to-use results calculation, reporting and exporting, and can run full Emperor programs created on PC.
  •  Intelligent torque cells rated at 100 mN.m, 200 mN.m, 300 mN.m, 1 N.m, 1.5 N.m, 3 N.m, and 6 N.m (14 ozf.in, 28 ozf.in, 42 ozf.in, 8.9 lbf.in, 13 lbf.in, 26.5 lbf.in, 53 lbf.in)
  •  Torque cell resolution: better than 0.01% of full scale
  •  Axial alignment: total runout (without fixtures), better than ±0.25 mm
  •  Speed from 0.1 to 30 rpm with resolution of ±0.1 rpm
  •  Sampling rates of 1 kHz, 500 Hz, 100 Hz, 50 Hz and 10 Hz
  •  Maximum displacement from tared position: 2500 revs
  •  Displacement accuracy: 0.1°
  •  Displayed resolution: 0.2°
  •  Throat depth (max sample radius): 111 mm, or 127 mm with bellows removed
  •  Headroom (without fixtures): 350 mm
  •  Dimensions: (with external weight hanger), Helixa-i: W 290 mm × H 758 mm × D 491 mm (Helixa-xt: W 587 mm)
  •  Weight: 28 kg (Helixa-i); 32 kg (Helixa-xt)
Accessories for this System
Torque reference bottle
Adapter to drive the Torque Reference Bottle calibration accessory
Reference bottle drive adapter
x-y positioning table for Helixa
X-Y positioning stage for use on Helixa QC motor spindle
Accurate closure torque measurement requires vertical movement and rigid drive to the mandrel
Mandrel Peg Drive, 54 mm